Weather Station Placement Planner

Enter the measurements for a spot you're considering. We check them against the published National Weather Service Cooperative Observer Program (COOP) siting requirements — the standard NOAA applies to its own volunteer network — and show you which guidelines the spot meets, which it does not, and by how much.

Everything runs in your browser. Nothing you enter here is sent anywhere or stored.

Temperature sensor and rain gauge follow different rules, so they are checked separately below. The COOP page states no siting rule for wind measurement, so this tool does not check one — we will not reuse the temperature rule as if it applied to wind.

Temperature sensor

All distances and heights in feet.

Guideline: 5 ft ± 1 ft

Guideline: at least 100 ft

Tree, fence, building

Guideline, when possible: distance ≥ 4× this height

Rain gauge (optional, separate standard)

A different, independent rule: the protection nearest the gauge must not be taller than 2× its distance from the gauge.

Guideline: at most 2× the distance

Result

Enter your measurements above — results update as you type.

Temperature sensor

  • Not checked yet:Temperature sensor height

    Enter a sensor height to check this.

    Guideline: 4–6 ft above ground (5 ft ± 1 ft)

    Exact wording of the standard
    The sensor should be mounted 5 feet +/- 1 foot above the ground.
    NOAA National Weather Service — Cooperative Observer siting requirements
  • Not checked yet:Temperature sensor clearance from obstructions(guideline, when possible)

    Enter both the obstruction's distance and its height to check this.

    Guideline: guideline, when possible: distance at least 4× the obstruction's height

    Exact wording of the standard
    When possible, the shelter should be no closer than four times the height of any obstruction (tree, fence, building, etc.).
    NOAA National Weather Service — Cooperative Observer siting requirements
  • Not checked yet:Temperature sensor distance from paved surfaces

    Enter the distance to the nearest paved surface to check this.

    Guideline: at least 100 ft from paved or concrete surfaces

    Exact wording of the standard
    The sensor should be at least 100 feet from any paved or concrete surface.
    NOAA National Weather Service — Cooperative Observer siting requirements

Rain gauge

  • Not checked yet:Rain gauge protection height

    Optional: enter the rain gauge's nearest protection distance and height to check this.

    Guideline: protection height at most 2× its distance from the gauge

    Exact wording of the standard
    The height of the protection should not exceed twice its distance from the gauge.
    NOAA National Weather Service — Cooperative Observer siting requirements

This is a site assessment against the COOP siting guidelines, not a certification. A typical home garden often cannot meet all of them — the 100 ft paved-surface guideline in particular. Not meeting one guideline does not make a spot unusable; it tells you which readings to treat with more caution.

Where these rules come from

Sensor height, obstruction clearance and paved-surface distance are stated in the National Weather Service's Cooperative Observer siting requirements under temperature sensor siting; the rain gauge guideline is stated separately under precipitation. Each result above shows the exact wording of the guideline it applied. The obstruction-clearance guideline is qualified by the source itself with “when possible”, so results there read “meets”/“does not meet this guideline”, not pass/fail — this is a site assessment against a professional research network's siting guidelines, not a certification. Most home gardens cannot meet the paved-surface guideline, and the tool says so plainly instead of marking every garden a failure.

Source: NOAA National Weather Service, Albuquerque — Proper Siting of Cooperative Weather Instrumentation, retrieved 2026-09-20.